Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent

Ask Latest Price
Video Channel
Brand Name :Chuangkang
Place of Origin :Jinan
MOQ :1 sets
Price :US$1000-US$3600
Payment Terms :T/T
Delivery Time :Within 7--15 Days for Common Size
Packaging Details :Carton
Certification :CE, ISO13485, FDA
Medical device advertisement approval number :20183661697
Types of medical device regulation :China's national machinery is approved for 20183661697
Medical device registration (filing) number :HD601492860001
Application :Hospital, Clinic, etc
Sample :Free
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Disposable Npwt (Negative Pressure Wound Therapy) Dressing Kit

Product Introduction

Product Structure:


ZN-50 intelligent trauma negative pressure comprehensive treatment instrument is portable, composed of host, negative pressure bottle and adapter.


Product performance:


1. Continuous use, stable performance. ZN-50 intelligent trauma negative pressure comprehensive treatment instrument conventional working negative pressure value of 80-120mmHg, digital display, using a new long-life vacuum pump, can run continuously for a long time.


2. Low noise, adjustable flow design. The noise is less than 55dB, no pollution, the air flow rate is 6~25L/min, and the work efficiency is high. Simple mode adjustment and dynamic control.


3. Alarm function, good safety. It has the functions of negative pressure and undervoltage alarm, negative pressure overpressure alarm, low voltage alarm, pipeline and wound blocking alarm, pipeline and wound air leakage alarm.


Technical advantages:


1) Double pressure display, double pressure control technology


Traditional negative pressure drainage, can only show the pressure of the negative pressure source, but also can only control the pressure of the negative pressure source, but can not display and control the pressure change of the wound treatment site we care about, the third generation of intelligent trauma negative pressure comprehensive treatment instrument can accurately display or control the pressure of the wound, clinicians can choose the size and control of negative pressure according to the nature of wound secretions, wound necrotic tissue.

2) Wound dressing/pipe blockage, air leakage monitoring technology


Wound dressing/duct obstruction is a common cause of negative pressure closure drainage treatment, and traditional negative pressure drainage cannot determine the obstruction of dressing and duct, but often affects the treatment effect. The third-generation intelligent trauma negative pressure comprehensive treatment instrument can accurately monitor the blockage and air leakage of wound dressing/pipeline, and has digital display and multiple alarm functions.


3) Gas shock and liquid flushing technology in closed wound


The third-generation intelligent trauma negative pressure comprehensive treatment instrument has semi-automatic and fully automatic wound dressing, gas shock and drainage, and liquid flushing and resistance. Effectively relieve and reduce wound dressing/tubing obstruction, ensure the effectiveness and reliability of trauma negative pressure treatment, and reduce the number of dressing changes.


It is equipped with semi-automatic and fully automatic negative pressure suction, gas or liquid perfusion treatment of wounds. For serious infections or special cases of wounds, there is no need to change dressings, no need to open the wound, clinicians can choose a variety of gases or prepare a variety of anti-inflammatory, sterilized, nutritional support and other therapeutic solutions, perfusion treatment of the wound, creating a new way to treat the wound.

2. Leading technology


1) Intelligent pressure control technology: microcomputer control, powerful software functions, can accurately execute various programs, control pressure and time within the program range.


2) Negative pressure pump ultra-low silence, ultra-long life. Even at night, treatment does not affect the patient's rest; Work for long periods of time for months without worrying about damage to the negative pressure pump.


3) Advanced wound sealing technology: a variety of specifications of supporting consumables, medical sponges and biological films with perfect functions, which can close patients with large-scale burns throughout the body to receive trauma negative pressure sealing and drainage treatment. It can also seal any small diabetic foot ulcer and receive effective trauma-negative pressure treatment.

Product Parameters
Model ZN50
Adapter input 100-240VAC 50/60Hz 2.0-1.0A
Adapter output 20VDC 8A
Maximum suction flow 8L/min
Type of safety protection BF type
The battery specification DC14.8V 5000mAh
Waterproof level IPX0
Device dimensions 300mm x140mm x 280mm
The host weight 3.5Kg
Pressure output range -30 to 180mmHg(4-24Kpa)
Working time 5min
The intermittent time 2min
Control the pressure fluctuation range Rated value ±10mmHg(1.33kPa)
Pressure accuracy error Less than ±10%

Product Description

Electric Negative Pressure Wound Therapy System Pump is a negative pressure drainage device for treating various breached or compromised surface wounds only used with Negative Pressure Wound Therapy System Dressing Sets. By generating regular intermittent negative pressure to create conditions for surgical repair.

Electric Negative Pressure Wound Therapy System Pump is portable and consists of main body(including an electric Negative pressure pump, PCBA, Rechargeable Battery), accessories( including Negative pressure Bottle, Power Adapter) and software.
There are two works style: pre-set work style, and physician setting work style. The pre-set work style is for conventional medical operation while physician setting work style is for medical staff to do clinical study.
The negative pressure value of conventional medical operation of the device is 80-120mmhg (10.66-15.99kPa). Under physician setting work style, the medical staff can freely adjust vacuum pressure from 4kPa to 24kPa (30-180mmHg) at 1mmHg (0.13kPa) step.
The digital display shows that the long-life negative pressure pump is adopted, which can run continuously for a long time, with noise less than 55dB, no pollution, air flow rate of 6-12L/min, and high work efficiency.

Electric Negative Pressure Wound Therapy System Pump is used with wound dressings to therapy wound. When the pump is turned on, the user will have 6 fix modes to choice to be suitable for different wound therapy. Also the user can use 7th physician-made mode, which negative pressure ranges from 30-180mmHg(4-24Kpa). All modes are intermittent therapy with 5min suction and 2min rest.
The device is programmed to work, and has notice functions as low voltage, tube/wound sealing air leak alarm, over-higher pump work
temperature.
Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent

Instructions for use

  1. Please read the manufacturer's instructions in detail and follow the instructions before using.
  2. Keep away from children, pets, pests, dust and lint because they may damage this device and/or affect its performance.
  3. Medical staff should be trained professionally prior to use this device
  4. Before starting the machine, be sure to no loose or leaking in every part or part joints.
  5. The main body should be kept dry. Do not wash in water. Should not be used in wet or splashed water environment.
  6. Do not operate this device if it has a damaged power cord, power supply or plug. If these components are worn or damaged, contact your local distributor..
  7. Do not drop or insert object into any opening or tubing of this product.
    Do not try to modify this product without authority permission.
  8. Do not connect this product to other devices that are not produced by our company.
    Do not spill liquid on any part of this product. In case of this happen, unplug the adapter if plugged in, then clean the liquid from this product. Ensure there is no liquid and nothing abnormal when starting the test machine. Otherwise, contact your local distributor.
  9. Do not use and/or store this product in or near these places where it can fall or be pulled into a tub, shower, bath, sink or toilet.
  10. Do not reach for this product that has fallen into water. Unplug the unit immediately if plugged in. Disconnect the unit from dressing and contact your local distributor.
  11. Cell phones or similar products could affect this product. Move this product away from these devices if interference is suspected.

The user must read the manual carefully before using the product.

Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent

Product acessories
Check that the probe and sealing plug of the negative pressure bottle should not be skewed, and slowly and horizontally push the negative pressure bottle into the installation position of the main body
 
Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent
Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent
Long press "shift mark/modify" button to check the working parameters of the equipment
Line 1: Display battery voltage (the power switch is on AC, this value is 0)
Line 2: Display the working current of the negative pressure pump (real-time monitoring of the negative pressure pump current, immediately stop the machine for protection if there is any abnormality)
Line 3:Display negative pressure pump temperature (real-time detection of negative pressure pump temperature, temperature above 36ºC will automatically open scattered
Hot fan, over 70ºC,Negative pressure pump shutdown protection)
If there is a sudden loss of pressure during the using of the machine, there is no need to worry that the liquid in the negative pressure bottle will flow back to the patient's part, because there is a duckbill valve device in the negative pressure bottle, which stipulates that the liquid can only flow from the outside of the negative pressure bottle to the inside of the negative pressure bottle, because its positive opening pressure is very low, and the reverse pressure is very high, so there will be no backflow
 
Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent

Replacement of negative pressure bottle

Remove : remove the negative pressure bottle from the left side of the machine, palm up, hook the handle of the blue cover of the negative pressure bottle with the index finger and middle finger of the left hand, hold the thumb against the shell, and pull it horizontally to the left slightly to take out the negative pressure bottle, as shown in the figure below
Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent

Installation: prepare the new negative pressure bottle, connect one end of the elbow of suction connection pipe to the suction port of the negative pressure bottle, and insert the negative pressure bottle buckle with the left palm to the negative pressure bottle cavity of the machine
Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent
Remove the battery fixing screw from the back shell of the machine with a cross screwdriver; Use thumb, index and middle finger cards
Live the battery buckle pull ring, thumb and index finger to close together; At the same time, the wrist is pulled outward in the direction perpendicular to the battery, that is, the battery can be removed, and a new battery can be replaced in the opposite way and be put into the machine
Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent

working principle

This device stores 6 commonly used negative pressure closed drainage treatment programs and a user-definable negative pressure treatment program in CUP of mainboard. When the power is turned on, a command is input from the therapeutic device screen and a treatment program accordingly. Then a driving circuit on the main board generates a certain frequency of current to act on the negative pressure pump to generate a negative pressure. During operation, the pressure sensor detects and monitors the negative pressure change, at same time these negative pressure information is transmitted back to the CPU. Through this dynamic control, the working frequency of the negative pressure pump is continuously kept relatively stable preset-value, thereby achieving the effect of negative pressure treatment.

Applications

Electric Negative Pressure Wound Therapy System Pump is intended to deliver negative pressure via the Negative-pressure Wound Therapy System Dressing Sets to the breached or compromised surface wound, in order for the removal of fluids, including wound exudates, irrigation fluids, body fluids and infectious materials, and is used only in hospital environment, not for civilian, household, ambulance and field hospital.

The device is applicable to the following treatment areas:
Acute wound.
Chronic and refractory wounds.
Wound surface requiring drainage due to excessive fluid leakage after surgery.

The device is forbidden use in such wound as:
Undebridable wound with necrotic eschar
Wounds with tumor tissue.
Fistula communicating with internal cavity viscera.
Wounds with large blood vessels or organs exposed.

Warranty Commitment

Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent
The company promises to provide warranty service within one year from the date of purchasing the equipment produced by the company. If the product itself has quality problems, the company has the right to choose to repair or replace the product without adding any cost to the user.
The company will not be jointly and severally liable for product damage caused by abuse, accident, improper operation or violation of instructions for use. The customer must return the warranty registration card to the company within 30 days after the product is damaged, otherwise it will be deemed invalid. Information such as invoices and product serial numbers must be filled in. The warranty card is limited to the original purchaser and cannot be transferred.
Wound Npwt Dressing Kit Negative Pressure Disposable NPWT Devices Intelligent

FAQ

1. What is the advantage of quality?
The company is furnished with developed equipment and technology from Germany, Belgium, and Taiwan (area).

2. What is MOQ?
30,00 pcs, It depends on the requirements of the products.

3. How to place an order?
Place an order with the salesperson
Make payment for deposit;
Sample making for confirmation before mass production;
After the sample is confirmed, mass production starts;
Goods are finished, inform the buyer to make payment for the balance;
Delivery.
Production time: 30-40 days.

4. What is your term of payment?
T/T is a regular payment (30% in advance, 70% before shipping).
Paypal and Western Union are just for a sample

Inquiry Cart 0